igusigus-icon-cart(0)

AIDA Cables

Ready-to-connect AIDA extension cables for automation

Here you will find all ready-to-connect extension cables suitable for the Automation Initiative of German Automobile Manufacturers (AIDA). This initiative specifies guidelines for the cabling between the control cabinet, the robot base and the moving robot axes. At last, this cable type is available as igus® readycable® for robot cabling in the automotive industry. and now offers ready-to-connect chainflex® cables for safe use in moving applications.
We offer AIDA cable configurations with HARTING push-pull components in different chainflex qualities. The extension cables offer further savings potential, as the usual junction boxes (female / female coupler) can be omitted.

All ready-to-connect cables are 100% tested and marked with a test seal.

 

Number of products 19

readycable® control cable according to AIDA Power, extension cable 7th axis, male/male

readycable® control cable according to AIDA Power, extension cable 7th axis, male/male
  • Requirements: For twistable applications
  • Outer jacket: PUR
  • Coolant resistant
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Halogen-free
  • Silicone-free
  • UV-resistant
  • PVC-free
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • chainflex® class: 5.1.3.3
CE
Cleanroom
DESINA
DNV-GL
EAC
flame retardant
NFPA
halogen free
Offshore
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
INR 16,130.89/Pc.Cost-effective price break available onlineINR 16,130.89/Pc. 1 Pc.

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® control cable according to AIDA Power, extension cable axis 1-6, male/male

readycable® control cable according to AIDA Power, extension cable axis 1-6, male/male
  • Requirements: For twistable applications
  • Outer jacket: PUR
  • Coolant resistant
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Halogen-free
  • Silicone-free
  • UV-resistant
  • PVC-free
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • chainflex® class: 5.1.3.3
CE
Cleanroom
DESINA
DNV-GL
EAC
flame retardant
NFPA
halogen free
Offshore
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
INR 16,130.89/Pc.Cost-effective price break available onlineINR 16,130.89/Pc. 1 Pc.

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® bus cable according to AIDA Profinet RJ-45, extension cable 7th axis, male/male

readycable® bus cable according to AIDA Profinet RJ-45, extension cable 7th axis, male/male
  • Requirements: For medium duty applications
  • Outer jacket: PUR
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Flame retardant
  • PVC-free
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • Halogen-free
  • chainflex® class: 4.3.3.1
CE
Cleanroom
DESINA
DNV-GL
EAC
flame retardant
NFPA
halogen free
Offshore
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UL Listed
UV resistant
INR 18,859.64/Pc.Cost-effective price break available onlineINR 18,859.64/Pc. 1 Pc.

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® bus cable according to AIDA Profinet RJ-45, extension cable axis 1-6, male/male

readycable® bus cable according to AIDA Profinet RJ-45, extension cable axis 1-6, male/male
  • Requirements: For twistable applications
  • Outer jacket: PUR
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Flame retardant
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • chainflex® class: 6.1.3.3
CE
Cleanroom
EAC
flame retardant
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
INR 20,327.60/Pc.Cost-effective price break available onlineINR 20,327.60/Pc. 1 Pc.

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® fibre optic cable according to AIDA Profinet LWL, extension cable 7th axis, male/male

readycable® fibre optic cable according to AIDA Profinet LWL, extension cable 7th axis, male/male
  • Requirements: POF fibres for heavy duty applications and interference-free transmission
  • Outer jacket: PUR
  • Halogen-free
  • Silicone-free
  • Coolant resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • UV-resistant
  • chainflex® class: 5.3.3.1
CE
halogen free
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UV resistant
INR 20,838.48/Pc.Cost-effective price break available onlineINR 20,838.48/Pc. 1 Pc.

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® data cable according to AIDA Signal, extension cable 7th axis, male/male

readycable® data cable according to AIDA Signal, extension cable 7th axis, male/male
  • Requirements: For heavy duty applications
  • Outer jacket: PUR
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 Notch-resistant Hydrolysis and microbe-resistant
  • Flame retardant
  • Halogen-free
  • Silicone-free
  • PVC-free
  • UV-resistant
  • chainflex® class: 5.5.3.1
CE
Cleanroom
DNV-GL
EAC
flame retardant
NFPA
halogen free
Offshore
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
INR 25,899.16/Pc.Cost-effective price break available onlineINR 25,899.16/Pc. 1 Pc.

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® data cable according to AIDA Signal, extension cable axis 1-6, male/male

readycable® data cable according to AIDA Signal, extension cable axis 1-6, male/male
  • Requirements: For twistable applications
  • Outer jacket: PUR
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Coolant resistant
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Silicone-free
  • UV-resistant
  • chainflex® class: 6.1.3.3
CE
Cleanroom
EAC
flame retardant
NFPA
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
INR 26,360.54/Pc.Cost-effective price break available onlineINR 26,360.54/Pc. 1 Pc.

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® bus cable according to AIDA Profinet RJ-45, extension cable 7th axis, female/female

readycable® bus cable according to AIDA Profinet RJ-45, extension cable 7th axis, female/female
  • Requirements: For medium duty applications
  • Outer jacket: PUR
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Flame retardant
  • PVC-free
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • Halogen-free
  • chainflex® class: 4.3.3.1
CE
Cleanroom
DESINA
DNV-GL
EAC
flame retardant
NFPA
halogen free
Offshore
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UL Listed
UV resistant
Upon request

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® control cable according to AIDA Power, extension cable 7th axis, male/male

readycable® control cable according to AIDA Power, extension cable 7th axis, male/male
  • Requirements: For twistable applications
  • Outer jacket: PUR
  • Coolant resistant
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Halogen-free
  • Silicone-free
  • UV-resistant
  • PVC-free
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • chainflex® class: 5.1.3.3
CE
Cleanroom
DESINA
DNV-GL
EAC
flame retardant
NFPA
halogen free
Offshore
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
Upon request

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® data cable nach AIDA Signal, extension cable 7th axis

readycable® data cable nach AIDA Signal, extension cable 7th axis
  • Requirements: For heavy duty applications
  • Outer jacket: PUR
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 Notch-resistant Hydrolysis and microbe-resistant
  • Flame retardant
  • Halogen-free
  • Silicone-free
  • PVC-free
  • UV-resistant
  • chainflex® class: 5.5.3.1
CE
Cleanroom
DNV-GL
EAC
flame retardant
NFPA
halogen free
Offshore
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
Upon request

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® bus cable according to AIDA Profinet RJ-45, extension cable axis 1-6, male/male

readycable® bus cable according to AIDA Profinet RJ-45, extension cable axis 1-6, male/male
  • Requirements: For twistable applications
  • Outer jacket: PUR
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Flame retardant
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • chainflex® class: 6.1.3.3
CE
Cleanroom
EAC
flame retardant
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
Upon request

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® control cable according to AIDA Power, extension cable 7th axis, male/male

readycable® control cable according to AIDA Power, extension cable 7th axis, male/male
  • Requirements: For twistable applications
  • Outer jacket: PUR
  • Coolant resistant
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Halogen-free
  • Silicone-free
  • UV-resistant
  • PVC-free
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • chainflex® class: 5.1.3.3
CE
Cleanroom
DESINA
DNV-GL
EAC
flame retardant
NFPA
halogen free
Offshore
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
Upon request

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® data cable according to AIDA Signal, extension cable axis 1-6, male/male

readycable® data cable according to AIDA Signal, extension cable axis 1-6, male/male
  • Requirements: For twistable applications
  • Outer jacket: PUR
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Coolant resistant
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Silicone-free
  • UV-resistant
  • chainflex® class: 6.1.3.3
CE
Cleanroom
EAC
flame retardant
NFPA
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
Upon request

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® bus cable according to AIDA Profinet RJ-45, extension cable 7th axis, male/male

readycable® bus cable according to AIDA Profinet RJ-45, extension cable 7th axis, male/male
  • Requirements: For medium duty applications
  • Outer jacket: PUR
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Flame retardant
  • PVC-free
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • Halogen-free
  • chainflex® class: 4.3.3.1
CE
Cleanroom
DESINA
DNV-GL
EAC
flame retardant
NFPA
halogen free
Offshore
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UL Listed
UV resistant
Upon request

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® control cable according to AIDA Power, extension cable 7th axis, male/male

readycable® control cable according to AIDA Power, extension cable 7th axis, male/male
  • Requirements: For twistable applications
  • Outer jacket: PUR
  • Coolant resistant
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Halogen-free
  • Silicone-free
  • UV-resistant
  • PVC-free
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • chainflex® class: 5.1.3.3
CE
Cleanroom
DESINA
DNV-GL
EAC
flame retardant
NFPA
halogen free
Offshore
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
Upon request

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® data cable according to AIDA Signal, extension cable 7th axis, male/male

readycable® data cable according to AIDA Signal, extension cable 7th axis, male/male
  • Requirements: For heavy duty applications
  • Outer jacket: PUR
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2 Notch-resistant Hydrolysis and microbe-resistant
  • Flame retardant
  • Halogen-free
  • Silicone-free
  • PVC-free
  • UV-resistant
  • chainflex® class: 5.5.3.1
CE
Cleanroom
DNV-GL
EAC
flame retardant
NFPA
halogen free
Offshore
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
Upon request

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® bus cable according to AIDA Profinet RJ-45, extension cable axis 1-6, male/male

readycable® bus cable according to AIDA Profinet RJ-45, extension cable axis 1-6, male/male
  • Requirements: For twistable applications
  • Outer jacket: PUR
  • Overall shield
  • Coolant resistant
  • Notch-resistant
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Flame retardant
  • Hydrolysis and microbe-resistant
  • UV-resistant
  • chainflex® class: 6.1.3.3
CE
Cleanroom
EAC
flame retardant
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
Upon request

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® control cable according to AIDA Power, extension cable 7th axis, male/male

readycable® control cable according to AIDA Power, extension cable 7th axis, male/male
  • Requirements: For twistable applications
  • Outer jacket: PUR
  • Coolant resistant
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Halogen-free
  • Silicone-free
  • UV-resistant
  • PVC-free
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • chainflex® class: 5.1.3.3
CE
Cleanroom
DESINA
DNV-GL
EAC
flame retardant
NFPA
halogen free
Offshore
oil resistance
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
Upon request

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

readycable® data cable according to AIDA Signal, extension cable axis 1-6, male/male

readycable® data cable according to AIDA Signal, extension cable axis 1-6, male/male
  • Requirements: For twistable applications
  • Outer jacket: PUR
  • Overall shield
  • Oil resistance: Oil-resistant according to DIN EN 50363-10-2
  • Coolant resistant
  • Notch-resistant
  • Hydrolysis and microbe-resistant
  • Flame retardant
  • Silicone-free
  • UV-resistant
  • chainflex® class: 6.1.3.3
CE
Cleanroom
EAC
flame retardant
NFPA
RoHs II (lead-free)
silicon free
UKCA
UL
UV resistant
Upon request

1 variant(s), of which:

igus-icon-lieferzeit
1 Delivery time on request

Consulting

I would be happy to answer your questions personally

Ravikumar Alloli
Ravikumar Alloli

igus-icon-phone+91 9342828642

Shipping and consultation

In person:
Monday to Friday from 8am - 8pm.

Online:
24h

Shopping at igus®